For Sale SEDECAL 2014 RadPro Optima Millennium 50kW Digital DR X-Ray Room, Canon CXDI-70C Wireless Detector, Toshiba Rad Room

For Sale SEDECAL 2014 RadPro Optima Millennium 50kW Digital DR X-Ray Room, Canon CXDI-70C Wireless Detector, Toshiba Rad Room
Location:Marlboro Township, NJ
or
Call (718) 915-7713
Description
Complete Component List:
1. SEDECAL SHF-535 X-Ray Generator
2. Floor Mounted Tube Stand
90–240V, 1ph, 24V, 50/60Hz, 0.4 KVA
3. Optima Millennium Elevating Radiographic Table
110–230V, 1ph, 50/60Hz, 0.6 KVA / 0.18 KW
4. Wall Bucky Stand
110–230V, 50/60Hz, 0.4 KVA / 24V
5. Toshiba Rotanode X-Ray Tube — E7254FX
6. Ralco R225 DHHS Beam Limiting Device (Collimator)
7. Claymount Expos-AID Automatic Exposure Control (AEC)
Integrated into table/bucky assembly
8. Mecalectro MF4020.05 Electromagnetic Brake Motor
24VCC, 18W, FM 50%
9. Canon CXDI-70C Wireless Flat Panel Detector
9–12V, 0.92A — 17"x17" wireless DR flat panel
10. Canon XB-1A Battery Packs (×2) + Dual Li-Ion Battery Charger
11. Virtual Imaging / Canon 555-NE Acquisition Workstation (Tower PC)
ASUS DVD-RW drive, dual NIC (DICOM/Canon labeled ports)
12. Canvys RAP2423AMII Medical-Grade Display Monitor
24V DC, 2.3A — UL classified medical display
13. APC Back-UPS 550 (BE550G)
550VA / 330W, 120V
Battery backup + surge protection for workstation
14. Accessories Included:
Keyboard and mouse
Network cables (Cat6 bundle, serial/DB25 cables)
Wall bucky mounting hardware (bagged)
Power cables
Integrated Console, no hard drive, no software.
Items are sold as-is with no returns or refunds available unless explicitly stated.
1. SEDECAL SHF-535 X-Ray Generator
2. Floor Mounted Tube Stand
90–240V, 1ph, 24V, 50/60Hz, 0.4 KVA
3. Optima Millennium Elevating Radiographic Table
110–230V, 1ph, 50/60Hz, 0.6 KVA / 0.18 KW
4. Wall Bucky Stand
110–230V, 50/60Hz, 0.4 KVA / 24V
5. Toshiba Rotanode X-Ray Tube — E7254FX
6. Ralco R225 DHHS Beam Limiting Device (Collimator)
7. Claymount Expos-AID Automatic Exposure Control (AEC)
Integrated into table/bucky assembly
8. Mecalectro MF4020.05 Electromagnetic Brake Motor
24VCC, 18W, FM 50%
9. Canon CXDI-70C Wireless Flat Panel Detector
9–12V, 0.92A — 17"x17" wireless DR flat panel
10. Canon XB-1A Battery Packs (×2) + Dual Li-Ion Battery Charger
11. Virtual Imaging / Canon 555-NE Acquisition Workstation (Tower PC)
ASUS DVD-RW drive, dual NIC (DICOM/Canon labeled ports)
12. Canvys RAP2423AMII Medical-Grade Display Monitor
24V DC, 2.3A — UL classified medical display
13. APC Back-UPS 550 (BE550G)
550VA / 330W, 120V
Battery backup + surge protection for workstation
14. Accessories Included:
Keyboard and mouse
Network cables (Cat6 bundle, serial/DB25 cables)
Wall bucky mounting hardware (bagged)
Power cables
Integrated Console, no hard drive, no software.
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.
Specifications
| Manufacturer | SEDECAL |
| Model | 2014 RadPro Optima Millennium 50kW Digital DR X-Ray Room, Canon CXDI-70C Wireless Detector, Toshiba |
| Condition | Used |
| Serial Number | X-Ray |
| Stock Number | 5780464 |
| Condition info | Used - Good |
| Type | Rad Room |
| Model | PC24045R / RAP2423AMII, Serial: DTO351D0084 |
| Input | 480V~, 3ph, 50/60Hz, 63 KVA |
| Output | 50 kW |
| Mfg | Canvys USA (Richardson Electronics) — August 2014 |
| Also labeled | Elevating Table A6563-01, Serial: SM31387M |
| Insert Model | E7254, Insert Serial: 4E626 |
| Unit Serial | 14F218 |
| Max Voltage | 150 kV, Focal Spot: 1.2 / 0.6 |
| Permanent Filtration | 0.8 Al/75, Stator: XS-RB |
| Rating | up to 150 kVp, Filtration: 2mm Al/75 |
| Supply | 12–45V DC or 20–30V AC, 30 VA |
| 4-field AEC | Field A, B, C + Master |
| Serial | 4B2040P47027 |
| FCC ID | AZDBM70659 |
| Battery | XB-1A, 12V / 0.25A each |
| Serials | 1010087 and 40418 |